Page 577 - Subyek Teknik Mesin - Forsthoffers Best Practice Handbook for Rotating Machinery by William E Forsthoffer
P. 577

Be st Practice 1 0.8          The Post-Shipment Phase: Installation, Pre-Commissioning, Commissioning and Start-up Best Practices

        Table 10.8.2 Lube system check list (example)dCont'd
        Item      Description                                  Specified value             Actual value Witnessed by

            6D.   L.P. case seal oil differential valve PDCV. Supply N 2 press, of  241 Kpa  _____
                  5PSIG at gas reference side of PDT and read differential press on
                  PDI
            6E.   HP case seal oil differential valve. Supply N 2 pressure of 30 PSIG at  241 Kpa
                  gas reference side of PDT and read differential press on PDI
        7.        Record the following:
            7A.   Pump disch. press on P.I.                    Approx. 2600               _____
            7B.   Oil temp. upstream on T.I.                   Less than 65 C             _____

            7C.   Oil temp. downstream on T.I.                 49
            7D.   Cooler/filter DP on PDI                       Less than
                  Switch transfer valve and record:            70 Kpa                     _____
                  Bank ‘A’ DP                                                             _____
                  Bank ‘B’ DP
            7E.   Lube press at console on P.I.                ) Approx. 283 Kpa          _____
            7F.   Control press at console on P.I.             ) 1091 Kpa                 _____
            7G.   LP case on DP PDI                            241 Kpad                   _____
            7H.   HP case on DP PDI                            241 Kpad                   _____
            7I.   Lube press at unit on P.I.                   124 to 138 Kpa             _____
            7J.   Control press at unit P.I.                   883 Kpa                    _____
            7K.   All ‘sight’ glasses show oil flow                                        _____
            7L.   Lube oil head tank is full                   e                          _____
            7M.   Turbine accumulator press on P.I.            ) Approx. 900 Kpa          _____
                  ) Adjust as required to attain proper values at the unit

        8.        Record seal oil drainer level for each drainer for one hour.
                  Drainer A                                    2 fills per hour            _____
                  Drainer B                                                               _____
                  Drainer C                                                               _____
                  Drainer D                                                               _____

        9.        Switch transfer valve from ‘A’ to ‘B’ bank and observe press            _____
                  fluctuation on P.I. and confirm that PSL does not actuate.

        10.       Bleed low side of filter switch PD SH and confirm PDAH actuates at  241 Kpa Rising  _____
                  specified value.
        11.       Bleed pressure off PSL (low oil press) and confirm @ unit annun. PAL  90 Kpa Falling
                  actuates at specified value. Read P.I.
        12.       Increase temporary N 2 press on PDSL (L.P. case seal low DP alarm  207 Kpa Falling  _____
                  switch) and confirm Annun. PDAL actuates at specified value. Read
                  PDI
        13.       Repeat above for PDSL (H.P. case seal low DP alarm) confirm  Falling     _____
                  Annun. PDAL actuates read on PDI
        (see note 2)
        14.       Bleed pressure off PSL (low oil trip switch) and observe:  76 Kpa Falling  ______
                  A. Annun. PALL functions Read PI
                  B. T&T valve closes
                  C. Valve rack closes

        15.       Increase temporary N 2 press on PDSLL (L.P. case seal low DP trip
                  switch) and observe that:
        (see Note 2)
                  A. Annun. PDALL functions. Read on PDI       138 Kpa Falling            ______
                  B. Action occurs as in 14 above





           548
   572   573   574   575   576   577   578   579   580   581   582