FOOTINGS, FOUNDATION WALLS, BASEMENTS, AND SLABS
of the foundation wall (Figure 6-21). This will allow room for support
of the veneer on the top of the foundation wall.
Figure 6-14 or 6-15 may be used to design concrete and masonry
foundation walls except when any of the following conditions exist:
■ The building official has determined that suitable backfill mate-
rial is not available.
■ Walls are subject to hydrostatic pressure from groundwater.
MAX 12"
MORE THAN 4'-0" UNBALANCED BACKFILL #4 STEEL
REINFORCING
BARS
8" 48"
MIN MAX
FIGURE 6-18
Minimum requirements for foundation walls in Seismic Zones 3 and 4 supporting more
than 4 ft. of unbalanced backfill. (from Council of American Building Officials One and
Two-Family Dwelling Code, Falls Church, VA).