Footings, Foundation Walls, Basements, and Slabs
                                                                                           209
                                          FOOTINGS, FOUNDATION WALLS, BASEMENTS, AND SLABS


            of the foundation wall (Figure 6-21). This will allow room for support
            of the veneer on the top of the foundation wall.
               Figure 6-14 or 6-15 may be used to design concrete and masonry
            foundation walls except when any of the following conditions exist:

               ■ The building official has determined that suitable backfill mate-
                  rial is not available.

               ■ Walls are subject to hydrostatic pressure from groundwater.













                             MAX  12"


               MORE THAN 4'-0"  UNBALANCED BACKFILL  #4 STEEL


                                                     REINFORCING
                                                     BARS





                                       8"             48"
                                     MIN               MAX














                                                                  FIGURE 6-18

            Minimum requirements for foundation walls in Seismic Zones 3 and 4 supporting more
            than 4 ft. of unbalanced backfill. (from Council of American Building Officials One and
            Two-Family Dwelling Code, Falls Church, VA).