Page 227 - Masonry and Concrete
P. 227

Footings, Foundation Walls, Basements, and Slabs




                                   NO OVERHANG OR GUTTER






                                  ROOF RUNOFF CONCENTRATED
                                  AT BLDG. PERIMETER




                                   NO GROUND SLOPE



                                 SOIL ADJACENT TO
                                 FOUNDATION SATURATED








                                  ROOF RUNOFF COLLECTED
                                  IN GUTTER


                                 OVERHANG PROTECTS
                                 PERIMETER



                                               DOWNSPOUTS CARRY
                                               ROOF RUNOFF AWAY
                                               FROM FOUNDATION

                                        GROUND SLOPES
                                        AWAY FROM
                                        BUILDING



                                   COMPACTED CLAY CAP WITH
                                   LOW PERMEANCE PROTECTS PERIMETER



                                                                                   FIGURE 6-34
                             Roof runoff. (from Joseph Lstiburek and John Carmody, Moisture Control Handbook, Van
                             Nostrand Reinhold).



                   Downloaded from Digital Engineering Library @ McGraw-Hill (www.digitalengineeringlibrary.com)
                              Copyright © 2004 The McGraw-Hill Companies. All rights reserved.
                               Any use is subject to the Terms of Use as given at the website.