Page 333 - Masonry and Concrete
P. 333

Masonry Garden Walls

             332   CHAPTER NINE


















                                                  a) SPECIAL PILASTER BLOCK
                                                                                   VERTICAL
                                                                                   REINFORCING
                                                                                   BAR GROUTED
                                                                                   INTO BLOCK
                                                                                   CORE





                                          ALTERNATING
                                             COURSES                       ALTERNATING
                                                                              COURSES







                                b) STANDARD UNITS IN PROJECTED,        c) INTEGRAL PILASTER IN
                                   INTERLOCKING BOND PATTERN             REINFORCED CORE

                               FIGURE 9-21
                              CMU pilasters (from Beall, Christine, Masonry Design and Detailing, 4th edition, McGraw-
                              Hill, New York).

                              supply a chemically compatible admixture for use in the mortar. When
                              treated units are not used, a clear water-repellent coating may be field
                              applied, but the wall will need to be recoated every few years to main-
                              tain its water repellency. Neither integral nor surface-applied water
                              repellents protect against water penetration through shrinkage cracks
                              or joint separations.
                                 Gray block can be painted with any type of breathable coating such
                              as acrylic latex house paint. The masonry should be allowed to cure for
                              at least 30 days before it is painted. Portland cement plaster or stucco



                   Downloaded from Digital Engineering Library @ McGraw-Hill (www.digitalengineeringlibrary.com)
                              Copyright © 2004 The McGraw-Hill Companies. All rights reserved.
                               Any use is subject to the Terms of Use as given at the website.