Page 255 - A Practical Companion to Reservoir Stimulation
P. 255
c
A Practical Companion to Reservoir Stimulation
Page Error
- -
A-12 In Table A-7, p should be 0.7 instead of 0.8.
B-7 In Table B-2, 0, should be 5300 psi instead of 5900 psi.
c-5 The last sentence of the first paragraph should read,
“Use the data for the gas well only.”
C-6 The result of Eq. C-20 should be 38.1 ft/sec instead of 3.8 1 ft/sec.
F-6 Replace Eq. F-28 with the following:
(44.1)( 375)( 1.1)( 1.2)
kfw =
1
I 1 0.5
I
L(0.12)( 1.2)(9x 10-6)(2) J
= 1700 md-ft.
Replace Eq. F-29 with the following:
1700
F- = 1.2
cD - (2) (700)