                       To determine the required canister number (RCN), the C  is divided by the amount of
                                                                     req
                       carbon contained in a single canister and rounded up to the next whole number. Typically,
                       each canister contains 150 lb of carbon.
                                            RCN = C /(150 lb carbon/canister)
                                                    req
                                            RCN = ________

                    Example 8
                                                                                             2
                       Outline the step-by-step procedures for calculating the steam requirements (lb steam/min-ft ),
                       of a fixed-bed carbon adsorption system.
                       Solution
                       The step-by-step procedures for calculating the steam requirements of a fixed-bed regen-
                       erative carbon system are summarized as follows:

                       Step 1: Carbon Adsorber Efficiency
                       For a given HAP outlet concentration (HAP ), the adsorption time (θ ), the regeneration
                                                          e                   ad
                       time (θ ),and the steam requirement (St) can be determined using Table 3.
                            reg
                                                     θ =_______h
                                                      ad
                                                    θ  =_______h
                                                     reg
                                                      St=________lb steam/lb carbon
                       Step 2: Steam Required for Regeneration

                       Calculate the steam requirement using
                                                   Q =NA [St(C' )/(θ  −θ      )]/60           (10)
                                                    s          req  req  dry-cool
                                                   Q =_______ lb/h
                                                     s
                       Calculate Q /A  :
                                s  bed
                                                   A   =Q' /U                                (10a)
                                                    bed   e,a  e
                                                   A   =______ft 2
                                                    bed
                                                 Q /A  =_________lb steam/min-ft 2
                                                  s  bed
                                                                2
                       Typically, the Q /A  is limited to 4 lb steam/min-ft to prevent fluidization of the carbon
                                   s  bed
                       bed. Assume Q    = 0.25h, if no information is available.
                                   dry-cool
                    Example 9
                       Determine the steam requirements of a fixed-bed regenerative carbon adsorption system
                       for air emission control.
                       The given data are as follows:
                                         RE = 95%

                                       HAP = 50 ppmv
                                           o
                                          St = 0.3 lb steam/ lb carbon (see Table 3)