Page 507 - Air Pollution Control Engineering
P. 507

12_ch_wang.qxd  05/05/2004  5:27 pm  Page 479
                    Emerging Pollution Control Technologies                                   479

                    will have lower pressure drop than filters in series, whereas series filter will achieve a
                    higher PM collection efficiency than filters in parallel. The housing unit for parallel filters
                    will be larger than the housing unit for series filters.

                    9.2. Application to Air Emission Control
                       The use of HEPA filters for the control of PM provides advantages/disadvantages,
                    which are listed in Table 3. A list of remediation technologies that are compatible with

                    Table 3
                    Advantages and Disadvantages of HEPA Filters
                                Advantages                              Disadvantages
                      • Easy to operate.                 • Many require prefilters for exhaust with high
                                                            PM concentrations.
                      • Provide 99.9% or greater PM removal  • Required housing units are expensive and may
                         efficiencies.                      be subject to corrosion.
                                                         • Filters are subject to fouling by high-humidity
                                                            exhaust gases.
                                                         • Filters must be replaced periodically because
                                                            of plugging caused by PM.
                                                         • High power costs because of pressure drop
                                                            across filter.




                    Table 4
                    Compatibilities of HEPA Filters with Remediation Technologies
                            Emission source                         Qualifications
                    Asbestos removal from building   During the asbestos removal, HEPA filters must either
                                                       be installed in the building ventilation system or in
                                                       the negative air pressure system.
                                                     A bag-out housing units will be required for HEPA
                                                       filters and filter must be disposed of properly.
                    Enclosure ventilation system     Inlet air with high PM concentrations may require
                                                       pre-filters.
                                                     Bag-out housing units may be required for
                                                       characteristics of PM (e.g, heavy metal or SVOC
                                                       contamination).
                                                     The lifetime of the HEPA filter will be shorten under
                                                       high-humidity application.
                    Hoods or enclosures of solidification/  Lime used in the process may subject the HEPA
                      stabilization mixing bins        housing to corrosion.
                                                     Inlet air with high PM concentrations may require
                                                       pre-filters.
                                                     Bag-out housing units may be required for
                                                       characteristics of PM (e.g. heavy metal or SVOC
                                                       contamination).
                                                     The lifetime of the HEPA filter will be shorten under
                                                       high humidity application.