Chapter 5: Shallow Well Drilling Applications 5-67 Figure 5-18: Minimum volumetric flow rate of air at API standard conditions for reverse circulation operations. Limited to solids weight rates of flow from 2.0 lb/sec to 3.0 lb/sec.