Page 343 - Air and Gas Drilling Manual
P. 343

8-26    Air and Gas Drilling Manual
                                   For this example, the length of the blooey line, L b, is
                                         = 200 ft
                                      L
                                       b
                               The inside diameter of the blooey line, D b, is
                                      d  = 8 097 inches
                                            .
                                       b
                                            d b
                                      D b  =
                                            12
                                             .
                                      D  = 0 668 ft
                                       b
                               The blooey line is  fabricated of commercial steel pipe,  therefore, the inside  surface
                               roughness is
                                      e p  = 0 00015 ft
                                            .
                               The Fanning friction factor for flow in the blooey line is determined from

                                                             2
                                                           
                                                  1        
                                      f b  =                                          (8-4)
                                                  D      
                                                    b
                                                       +1 14
                                                 
                                                     
                                            2 log.         
                                                 e       
                                                    p
                               Equation 8-4 becomes
                                                               2
                                                              
                                      f  =          1         
                                       b         0 668      
                                                    .
                                           2 log       +114 
                                                            .
                                                0 00015     
                                                   .
                                            .
                                      f b  = 0 014
                               The inside cross-sectional area, A b, of the blooey line is
                                            π
                                      A b  =     D b 2
                                            
                                             4
   338   339   340   341   342   343   344   345   346   347   348