                                   The total length of the lumped drill pipe tool joints  geometry increment, H 2, in
                               the cased section is
                                      H 2   350 ft
                               The  inside  diameter  of  the  drill  pipe  tool  joints  lumped  geometry  in  this  cased
                               section is
                                      D     0 292 ft
                                            .
                                        6
                                   The total length of the lumped drill  pipe body geometry increment, H 1, in  the
                               cased section is
                                            ,
                                      H 1   6 650 ft
                               The inside diameter of the drill pipe body lumped geometry in this cased section is
                                            .
                                      D  7  0 319 ft
                                 Inside the Drill String (10,000 ft to 7,000 ft)
                                   The  fifth  drill  string  section  increment  is  denoted  by  the  length  H 5.    The
                               temperature  at  the  bottom  of  the  drill  collars  (bottomhole  temperature)  in  the
                               openhole section is
                                      T 5  604 41˚R
                                              .
                               The average temperature of the drill collar length H 5 and, thus, the temperature of the
                               aerated fluid flow inside the drill collars is

                                      T     601 91˚R
                                               .
                                       av5
                                   In  order  to  obtain  the  approximate  value  of  the  Fanning  friction  factor  for
                               Equation 6-102, it is necessary to estimate the Reynolds number and, thus,  the flow
                               conditions inside the drill  collars along H 5.  This  is  accomplished  by  determining
                               the Reynolds number at the entrance end of the inside of the drill  collar section and
                               assuming this  Reynolds number approximates  the  flow  conditions  throughout  the
                               inside of the drill collar section.
                                   The absolute viscosity of the gas (air) at atmospheric conditions,   , is
                                                                                    g
                                            .
                                            0 012 cps
                                       g
                                                  0
                                                        0
                                            0
                                           (.012 ) (.001 ) (.02089 )