Page 120 - Analytical method for food addtives
P. 120

70  Analytical methods for food additives


              Table 7.3  Performance characteristics for benzoic acid in almond paste, fish
                                  1
              homogenate and apple juice  (JAOAC (1983) 66, 775, NMLK collaborative study)
              Samples                       Almond paste               Fish homogenate               Apple juice

              No. of laboratories  8    8        8        8        6       8
              Units          mg/kg    mg/kg    mg/kg    mg/kg    mg/kg    mg/kg
              Mean value      982     1987      501     2044      41      1001
              S               36       62       14       40       2.6      9.4
               r
              RSD            3.7 %    3.2 %    2.8 %    2.0 %    6.1 %    2.7 %
                  r
              S               33       83       27       76       5.8      32
               R
              RSD            4.7 %    5.3 %    6.1 %    4.3 %    14.7 %   3.5 %
                  R
              Ho             0.83      1.04     0.97     0.85     1.62    0.61
                R
              Av recovery   100.4 %   98.8 %  100.1 %   98.3 %  105.9 %  94.4 %
              Key
              Mean The observed mean. The mean obtained from the collaborative trial data.
              r    Repeatability (within laboratory variation). The value below which the absolute difference
                   between two single test results obtained with the same method on identical test material under the
                   same conditions may be expected to lie with 95 % probability.
              S r  The standard deviation of the repeatability.
              RSD The relative standard deviation of the repeatability (S  × 100/mean).
                                                     r
                 r
              R    Reproducibility (between-lab variation). The value below which the absolute difference between
                   two single test results obtained with the same method on the identical test material under different
                   conditions may be expected to lie with 95 % probability.
              S R  The standard deviation of the reproducibility.
              RSD The relative standard deviation of the reproducibility (S  × 100/mean).
                                                      R
                 R
              Ho   The HORRAT value for the reproducibility is the observed RSD  value divided by the RSD
                R                                           R                 R
                   value calculated from the Horwitz equation.