Page 49 - Assurance of Sterility for Sensitive Combination Products and Materials
P. 49

Terminal sterilization   37


              gas, and dry/moist heat, allowing robust sterilization cycles to be developed.
              An in-depth understanding of microbial loading along with microbial re-
              sponse to the sterilant resulted in conservative cycles that produced safe
              products. Innovative new products are pushing current sterilization tech-
              nology to the limits, as developers are challenged to address new materials,
              and new drugs with complex designs. These advances are pushing the ster-
              ilization technology to new limits. As developers continue to innovate in
              areas such as controlled drug delivery, sensitive combination product that
              provide multiple benefits, and the incorporation of electronics into devices,
              the sterilization technology and validation strategies will have to be as in-
              novative to match the needs of these devices.


              References
                [1]  R.A. Molins, Food Irradiation: Principles and Applications, Wiley & Sons, May 24,
                 2001, (ISBN: 0-471-35634-4).
                [2]  D. M. Boyd, An Evaluation of Radiation-Processed Foods for Military Rations, De-
                 fense Technical Information Center Compilation Part Notice ADP014623.
                [3]  ANSI/AAMI ST67:2011 (R2017), Sterilization of Health Care Products—Require-
                 ments and Guidance for Selecting a Sterility Assurance Level (SAL) for Product Labe-
                 led Sterile.
                [4]  W. Rutala, D.J. Weber, CDC Guidance for Disinfection and Sterilization in Healthcare
                 Facilities, HICPAC, 2008.
                [5]  ISO 11137-1 Sterilization of Health Care Products-Radiation-Part 1: Requirements
                 for Development, Validation, and Routine Control of a Sterilization Process for Medi-
                 cal Devices.
                [6]  BS EN ISO 11135-1:2014 Sterilization of Healthcare Products-Ethylene
                   Oxide-Requirements for Development, Validation and Routine Control of a Steriliza-
                 tion Process for Medical Devices (ISO 11135:2014).
                [7]  J. Broad, L. Nawrocki, Making Sure its Sterile, Medical Design, July 1, 2006.
                [8]  M. Karel, D. B. Lund, Physical Principles of Food Preservation, CRC Press, (June 20,
                 2003, ISBN:0824755790).
                [9]  J.F. Diehl, Safety of Irradiated Foods, CRC Press, Karlsruhe Germany, ISBN, Dec 1,
                 1999, pp. 0–8247-93447.
                [10]  Institute Archives, M.I.T.  Libraries, December,  https://libraries.mit.edu/mithistory/
                 research/schools-and-departments/school-of-science/department-of-biology/, 1995.
                [11]  M. Curie, Sur l’etude des courbes de probabilite relatives a l’action des rayons X sur les
                 bacilles, Compt. rend. Aca. Paris 188 (1929) 202.
                [12]  M.F. Holweck, Production de rayons X monochromatiquies de grand longueur d’onde.
                 Action quantique sur les microbes, Compt. rend. Aca. Paris 188 (1929) 197.
                [13]  M.A. Lacassagne, Action des rayons X de grande longueur d’onde sur les microbes.
                 Establissement de statistiques precises de la mortalite des bacteries irradiees, Compt.
                 rend. Aca. Paris 188 (1929) 200.
                [14]  Sister Mary Andre Chorzempa, Ionizing Radiation and its Chemical Effects: A His-
                 torical Study of Chemical Dosimetry (1902–1962), Oregon State University, June
                 1971.
                [15]  J. Silverman, Radiation processing: The industrial applications of radiation chemistry, J.
                 Chem Ed 58 (1981) 168–173, https://doi.org/10.1021/ed058p168.