Relevant factors for redevelopment                                121

           codes in force. Lack of compliance, for example, with life safety code requirements
           (see Glossary) would exclude some reuse options. Structural codes have been written
           for new constructions and leave little tolerance for existing features like open stair-
           wells and steeper stairs. Meant to provide safe egress in case of fire or panic, they
           usually require more space than what normally exists in old constructions. Special
           problems can occur when trying to comply with such standards as Americans with
           Disabilities Act (US Department of Justice, 2010). Not only do these standards require
           an additional area (leaving less for the main use of the building), but also there is a
           higher cost for remediation. The rigidity of building codes in their requirements for
           reusing buildings is a sore point. Any regulatory relaxations for adaptive reuse should,
           however, be weighed against extra risks to the health and safety of those living or
           working in the reused building. Moreover, failing to upgrade existing buildings to
           modern standards limits the market performance of a building. Basically, sustainable
           buildings perform better economically, socially, and environmentally.
              The challenges of code compliance, if anticipated at an early stage, can be success-
           fully dealt with through careful planning and imagination (the latter is an essential
           ingredient in almost all reuse projects). It is important to understand that there is often
           more than one way of achieving a desired outcome—consultants such as building sur-
           veyors, decontamination experts, architects, and engineers need to be creative. At
           Carriageworks, Sydney, a sprinkler system was developed to skip the requirement
           to fire-rate the steel structure (Heritage Council of Victoria, 2013).
              It is very hard to guess beyond what you can see without some ad hoc investiga-
           tions. An old boiler system and its piping will quite certainly contain asbestos. This of
           course must be removed and will represent an additional conversion expense. Old wir-
           ing and plumbing are likely to be removed in any case. Another component in likely
           need of replacement is the roof.
              Often the minimum buildings standards are restrictive to adaptive reuse, while at
           times a structural code can de facto block redevelopment. In practice such strict codes
           can force a developer to demolish an existing building, so that a building can be con-
           structed from scratch. Variances or waivers are legal means to get out of certain build-
           ing code requirements.
              A significant reform in the regulation of work in existing buildings was launched in
           1998 in New Jersey with the adoption of the New Jersey Uniform Construction
           Code—Rehabilitation Sub-code. New Jersey became the first US State with a com-
           prehensive code specifically aimed to assist the redevelopment of existing buildings
           into housing. A chapter dedicated to historic buildings outlines greater flexibility for
           historic structures.
              The subcode is based on the principle that historic buildings do not have to mimic
           new constructions in detail in order to be safe and accessible (Cantell, 2005).


             Flexibility in Reuse: Regulations Can Change (National Clearinghouse
             for Educational Facilities, 2003)
             Adaptive reuse has been hard to implement for Californian schools. California’s seismic require-
             ments for public schools required a special review of design documents followed by compliance