Page 100 - Build Your Own Combat Robot
P. 100

It’s All About Power
                                                                                Chapter 5:
                                    from which to draw the current. You might ask yourself, “Do I really need to buy a  81
                                    battery to test what size battery I need?” Yes, you do, if you want to be able to mea-
                                    sure the current draw. The battery voltage of this test battery must not droop while
                                    testing for the current draw. In other words, the voltage must remain constant
                                    throughout the tests. The advantage of using a large lead acid battery for the current
                                    draw tests is that, because it will provide a long run time, you can use this battery
                                    during the initial testing phases of the robot. After you have selected the appropriate
                                    batteries for your robot, you can use them for all of the final test phases.
                                      In most cases, fighting robots will draw a lot of current—much more than the
                                    maximum current rating of most multimeters. The best tool to use to measure the
                                    current draw is a high-current ammeter capable of measuring more that 100 amps.

                              Using Ohm’s Law to Measure Current Draw

                                    You can also measure the resistance of the motor and calculate the current draw
                                    from this measurement using Ohm’s Law. The formula to do this is current = volt-
                                    age/resistance.Thisformuladoesn’tnecessarilyprovideareliablemeasure,however,
                                    because, first, the resistances are very low for competition motors and most ohm
                                    meters are not accurate at such low resistance levels. Second, if this measurement
                                    is made accurately, it must be made considering the resistances of the complete
                                    wiring harness, motor drivers, and motor. Last, even if the measurement is done
                                    accurately, the calculated current will be much higher than actual due to frictional
                                    and heat losses.
                                      In all fairness, if measured accurately, the peak motor currents can be deter-
                                    mined using an ohm meter and this formula:

                                                                                                    5.1

                                      Here, the current, I, is in amps; the voltage, V, is in volts; and the resistance, R,
                                    is in ohms. To use this method, place a high-power, small-resistance-value resistor
                                    in series with your robot’s battery supply. Then, using a voltmeter, measure the
                                    voltage across this resistor.

                              Suitable Resistor and Measurement Basics

                                    If you have access to a low-value, high-wattage resistor, you should use it to per-
                                    form your measurements—but resistance, high-wattage resistors are hard to find.
                                    The resistance should be less than 0.01 ohms. If your motor’s expected peak cur-
                                    rent draw is 100 amps, you will need at least a 100-watt resistor. If you don’t have
                                    access to such a resistor, a 0.01-ohm resistor can be made with 6.2 feet of readily
                                    available #12 copper wire. The wire needs to be slightly longer than 6.2 feet, but
                                    you can connect the voltmeter at the place on the wire that is 6.2 feet from the bat-
                                    tery. In addition, it is a good idea to keep the insulation on the wire and to coil up