Page 154 - Centrifugal Pumps Design and Application
P. 154

132    Centrifugal Pumps: Design and Application






































        Figure 9-14. Vertical pump assemblies (courtesy BW/IP International, Inc.
        Pump Division, manufacturer of Byron Jackson/United™ Pumps).






        bricated and the other bearings lubricated by the pumped liquid. This de-
        sign lends itself well to smaller pumps with up to 18-inch bowl diameter
        and 2-inch shaft diameter. However, the following limitations must be
        noted:

        * Taper collet mounting of impellers, depending on shaft diameter and
          material combinations, is only recommended for handling liquids from
          0°F to 200°R The same temperature limitation applies to semi-open
          impellers.
        * A grease lubricated bottom bearing is only recommended for ambient
          temperature water service; otherwise, lubrication with the pumped liq-
          uid should be used with filtration when required.
   149   150   151   152   153   154   155   156   157   158   159