Page 45 - Centrifugal Pumps Design and Application
P. 45

3









                                       Impeller


                                        Design









          In this chapter detailed information for designing a centrifugal pump
        impeller will be presented. This information will apply to a new design
        where a model in the same specific speed is not available. The design
        factors shown are based on a theoretical approach and many years of col-
        lecting thousands of performance tests in various specific speeds.
          The following example, will demonstrate the procedure necessary to
        design and layout a new impeller.




        Example

            The requirements for a new pump are shown on curve Figure 3-1,
          which at Best Efficiency Point (BEP) is:

            2,100 GPM—450 ft-3,600 RPM-Liquid—Water

          Step 1: Calculate pump specific speed.
   40   41   42   43   44   45   46   47   48   49   50