8.3 Basic control theory    93




                  8.3.3 Proportional controller

                  A controller whose action is proportional to the error signal is called a proportional
                  controller. This controller has the form
                                               f
                                        ftðÞ ¼ K p X set  X m g ¼ K p etðÞ       (8.2)
                  where K p is called the proportional constant. Fig. 8.5 shows an illustration of propor-
                  tional control action.
                     In general, both positive and negative control actions may occur. A dead-band
                  may be used to avoid frequent switching of the control action. Fig. 8.6 illustrates
                  a proportional controller with a dead-band and a cut-off at the controller limit.



                                             f(t)





                                                      f(t) = K.e(t)


                                               0                         e(t)
                  FIG. 8.5
                  A typical proportional controller.




                                              f(t)
                                                                   Controller limit






                                                  0
                                              Dead Band            Error, e(t)









                  FIG. 8.6
                  A proportional controller with a dead-band and a limit.