Page 424 - Forensic Structural Engineering Handbook
P. 424

CONCRETE STRUCTURES                  12.15






















                         FIGURE 12.10  Field load test of precast double T-beam. (Courtesy of CTL
                         Group)





























                    FIGURE 12.11  Laboratory test to destruction of precast double T-beam. (Courtesy of George
                    Pfoertner Photography.)

             in the laboratory. Figure 12.11 shows a test to destruction of a full-size double tee. In
             conducting a test of this sort, instrumentation of all strands should be provided to determine
             if there is premature bond slip. Figure 12.12 shows an example of instrumentation on the
             strand.
               Load testing to destruction provides information concerning flexural strength and shear
             strength, as well as bond slip.