Page 156 - Formulas and Calculations for Petroleum Engineering
P. 156

Drilling engineering formulas and calculations Chapter  2  149



             Formula(s)

                                                              y   L
                                                         P ¼
                                                          m
                                                             300   d
             Reference: Lapeyrouse, N. J., 2002, Formulas and Calculations for Drilling, Production and Workover, Second Edition,
             Gulf Professional Publishing, Page: 79.

             2.178 Pressure required to overcome mud’s gel strength in annulus

             Input(s)
                                                     2
                y:   Gel Strength of Drilling Fluid (lb/100 ft )
                D h :  Hole Diameter (in.)
                D p :  Pipe Diameter (in.)
                L:   Length of Drillstring (ft)

             Output(s)

                P m :  Pressure Required (psi)

             Formula(s)

                                                              y   L
                                                     P ¼
                                                      m
                                                         300   D  D  p
                                                                 h
             Reference: Lapeyrouse, N. J., 2002, Formulas and Calculations for Drilling, Production and Workover, Second Edition,
             Gulf Professional Publishing, Page: 79.


             2.179 Pump calculation—Pump pressure
             Input(s)

                P d :  Frictional Pressure Losses (psi)
                DP:   Bit Pressure Drop (psi)


             Output(s)
                P p :  Pump Pressure (psi)


             Formula(s)

                                                         P ¼ DP+ P d
                                                          p

             Reference: Samuel. E Robello. 501 Solved Problems and Calculations for Drilling Operations. Sigma Quadrant. 2015.
             Houston, Texas, Page: 69.


             2.180 Pump calculations—Power required
             Input(s)

                Q:   Flow Rate (gpm)
                DP:   Bit Pressure Drop (psi)
   151   152   153   154   155   156   157   158   159   160   161