Page 68 - Fundamentals of Enhanced Oil and Gas Recovery
P. 68

56                                                        Ehsan Mahdavi and Fatemeh Sadat Zebarjad


                sandstones are more favorable in ISC process. Crude oils with viscosities higher than
                1500 cp are recommended for a preheating treatment (e.g., by CSS method). ISC is
                not commercially approved to be used as tertiary recovery after waterflooding and is
                known as a potentially hazardous treatment when it is used on a wrong formation.
                Detailed screening criteria are illustrated in Table 2.1.



                REFERENCES
                 [1] T.F. Stocker, et al., 1535 pp Climate Change 2013: The Physical Science Basis. Contribution of
                    Working Group I to the Fifth Assessment Report of the Intergovernmental Panel on Climate
                    Change, Cambridge University Press, Cambridge, UK, and New York, 2013.
                 [2] V. Alvarado, E. Manrique, Enhanced oil recovery: an update review, Energies 3 (9) (2010)
                    1529 1575.
                 [3] R.T., Johns, B. Dindoruk,, Gas flooding, Enhanced Oil Recovery Field Case Studies, Gulf
                    Professional Publishing, Elsevier, 2013, pp. 1 22.
                 [4] E. Mahdavi, et al., Experimental investigation on the effect of asphaltene types on the interfacial
                    tension of CO 2  hydrocarbon systems, Energy Fuels 29 (12) (2015) 7941 7947.
                 [5] E. Mahdavi, et al., Effects of paraffinic group on interfacial tension behavior of CO 2  asphaltenic
                    crude oil systems, J. Chem. Eng. Data 59 (8) (2014) 2563 2569.
                 [6] L. Koottungal, Worldwide EOR survey, Oil Gas J. 110 (2012) 57 69.
                 [7] V. Kuuskraa, QC updates carbon dioxide projects in OGJ’s enhanced oil recovery survey, Oil Gas J.
                    110 (7) (2012) 72.
                 [8] J.J. Taber, F. Martin, R. Seright, EOR screening criteria revisited-Part 1: introduction to screening
                    criteria and enhanced recovery field projects, SPE Reservoir Eng. 12 (03) (1997) 189 198.
                 [9] G. Moritis, EOR continues to unlock oil resources, Oil Gas J. 102 (14) (2004) 49 52.
                [10] Awan, A.R., Teigland, R., Kleppe, J. A Survey of North Sea Enhanced-Oil-Recovery Projects
                   Initiated During the Years 1975 to 2005, SPE Reservoir Evaluation & Engineering 11 (03), 2008,
                   497 512.
                [11] Demin, W., et al., 1999. Summary of ASP pilots in Daqing oil field. SPE Asia Pacific Improved Oil
                   Recovery Conference. Society of Petroleum Engineers.
                [12] C. Cadelle, et al., Heavy-oil recovery by in-situ combustion-two field cases in Rumania, J. Pet.
                   Technol. 33 (11) (1981) 2. 057-2,066.
                [13] Li, H., et al., 2003. Alkaline/surfactant/polymer (ASP) commercial flooding test in central xing2
                   area of Daqing oilfield. SPE International Improved Oil Recovery Conference in Asia Pacific.
                   Society of Petroleum Engineers.
                [14] A. Al Adasani, B. Bai, Analysis of EOR projects and updated screening criteria, J. Pet. Sci. Eng. 79
                   (1) (2011) 10 24.
                [15] J.J. Sheng, Cyclic steam stimulation, Enhanced Oil Recovery Field Case Studies, Gulf Professional
                   Publishing, Elsevier, 2013, pp. 389 412.
                [16] Doleschall, S., Szittar, A., Udvardi, G., 1992. Review of the 30 years’ experience of the CO 2
                   imported oil recovery projects in Hungary. International Meeting on Petroleum Engineering.
                   Society of Petroleum Engineers.
                [17] G. Moritis, Worldwide EOR survey, Oil Gas J. 106 (2008) 41 42. 44 59.
                [18] J. Taber, F. Martin, R. Seright, EOR screening criteria revisited—part 2: applications and impact of
                   oil prices, SPE Reservoir Eng. 12 (03) (1997) 199 206.
                [19] L. Sibbald, Z. Novosad, T. Costain, Methodology for the specification of solvent blends for miscible
                   enriched gas drives (includes associated papers 23836, 24319, 24471 and 24548), SPE Reservoir
                   Eng. 6 (03) (1991) 373 378.
                [20] Redman, R.S., 2002. Horizontal miscible water alternating gas development of the Alpine Field,
                   Alaska. SPE Western Regional/AAPG Pacific Section Joint Meeting. Society of Petroleum
                   Engineers.