Page 616 - Handbook of Electrical Engineering
P. 616

INDEX    609

             ONAN 12                                         Root mean square 409
             TEFC 80                                         Short circuit withstand 473
             Water  121, 139                                 Stalling, of induction motors 341
           Coordination, of contactors and fuses 155         Stray  372
           Coordination, see also contactors                 Sub-transient fault 151
             Complete for molded case circuit breakers       Symmetrical  174
                 167, 450                                    Threshold, for molded case circuit breakers
             Of cascaded devices 451                             164
             Of fuses and molded case circuit breakers       Through-fault 329
                 450
                                                             Transformer  311
             Poor  451                                       Transformer, core-balance  333, 340, 343,
             Underfrequency relays 540, 543                      345
           Copper                                            Transformers, star/delta interposing 322
             Annealed 184                                    Transient fault 151
             Hard-drawn  184                                 Unbalanced 142
             In cables as conductors 192, 193
                                                             Zeros and crossing points 79, 274, 502
           Copper and copper alloy 63
                                                           Current contribution
           Copper, bonding conductors for earthing 354
                                                             Sub-transient fault 151
           Corner mesh voltage 369
                                                             Transient fault 151
           Corner step voltage 369
           Coupling, loose and tight 303, 306              Current rating
           Crushed rock used in earthing systems 367         Busbar normal  8
           Cubicle                                           Fault 8
             Type of switchgear 147, 371                   Cylindrical rotor construction 61
             Earthing of  382
           Current                                         Damper bars  63, 68
             Asymmetrical  174                             Damper windings 480, 490
             Charging of capacitance in long feeder        Damping  84
                 cables  72, 340, 357                      Damping characteristics 304
             Constant, in inverters 423                    Damping feedback  88, 539
             Decrement of short circuit 277, 492           DC off-set current  151, 293, 492, 502
             Derated for cables 243                        DC off-set of fault current  149
             Doubling 274, 283                             DC link capacitor  398, 422
             Full-load 230                                 DC link inductor 398, 422
             Fundamental  142
                                                           DC motors 385, 394, 401, 407
             Fundamental instantaneous 409
                                                           Deceleration factor  118
             Harmonic and stray, in generator neutral
                                                           Decrement of fault currents  300, 315
                 circuit 324
                                                           Deep-bar effect, and factor  101, 102, 400,
             High-set 329
             High starting 336                                 480, 500, 502, 503
             Instantaneous 142                             Definite time delay 318
             Inrush, of motors 340                         Delay angle  404, 408
             Inrush, of transformers  141                  Delta connected motors 392
             Negative phase sequence 322, 339              Derating, see Factors
             Noise pick-up 373                             Diesel
             Noise pick-up in earthing busbars 382           Engine 19
             Nominal, of relays  348                         Generators 3
             Overloading 242                               Diesel engines, emergency  449
             Peak short-circuit 145                        Diesel generators, emergency  459
             Plug setting 348                              Dimensions, influence on reactances  67
             Positive sequence  339                        Direct-on-line starting 107, 124, 176, 312,
             Rated, of cables 199                              318, 336, 441, 500, 573, 580