INDEX    617

             Amplifier  54, 84                                Field winding earth fault 326
             Consumption 9                                   Inverse time  124
             Factor of load 5                                Lock-out 436
             Factor of the fundamental current 410           Long time delay characteristic 163
             Invariance in generalised machines 484          Negative phase sequence current 322, 326
             Management system 435                           Nominal current 348
             Net available from the power turbine 26         Overvoltage 318
             Reactive  69, 83, 443                           Restricted earth fault 323
             Reactive in harmonic systems 410                Reverse power 448
             Reactive, summation in estimating load          Sensitive earth current 596
                 199                                         Short time delay characteristic  163
             System frequency  441                           Synchronising check 158
             System, fully loaded 311                        Thermal  124, 337
             System, lightly loaded 311                      Undervoltage 159, 318, 335
             Systems, national grid 431                      Voltage restrained overcurrent  316
             Transistors and thyristors 385, 402           Protective relays and devices  311
             Transistors controllers 391, 394                Cascaded devices 451
             Utility company  328                            IEEE numbers 313
           Potential gradient, maximum in cable              Notation used for 313
               insulation 373                              Protection schemes and systems
           Potential difference in earthed systems 355       Back-up  318, 333
           Power angle chart 72                              Cold and hot thermal, for motors 340, 344
           Power factor  64, 85                              Coordination 312
           Power factor leading 73                           Coordination of earth fault devices 333
           Power factor of a transformer  140                Core-balance  242, 333, 345
           Power factor of short circuit current  174        Core-balance for fluorescent lighting 346
           Power-to-weight ratio 20                          Core-balance for static loads 346
           Power-to-weight ratio, high 19, 20                Core-balance for welding socket outlets
           Power turbine 19                                      346
           Power utility company  8, 20                      Definite time  316
           Pre-arcing time  174                              Differential busbar zone 334
           Pressure drops 32                                 Excessive vibration in motors 342
             Combustion chamber  33                          Fuses  333
             Compressor discharge  33                        High-set overcurrent for static loads 346
             Turbine exhaust 33                              High-set current  330
           Pressure ratio 31, 33                             High bearing temperature of motor  342
           Prime-movers  13, 304                             High speed differential current  333
             Gas turbines 41                                 Instantaneous current 330, 332
             Under and over frequency  325                   Instantaneous overcurrent for static loads
             Upgrading 13                                        346
           Projects, new 5                                   Instantaneous tripping function 339
           Prospective current in fuses 176                  Inverse square law  330
           Prospective fault current  79                     Loss of excitation 320
           Protective relays                                 Merz-price scheme  333
             Admittance type 320                             Multi-zone distance 332
             Buchholz 139, 398                               Of high voltage motors 336
             Coordination 312                                Overcurrent and overvoltage in battery
             Differential stator current  80, 318, 326           charger  452
             Earth fault 124                                 Overcurrent in cables 332
             Earth leakage current  451                      Overcurrent in inverters 450
             Earth leakage detection 242, 323                Overcurrent in the bus-section circuit 335
             Electronic 336                                  Overloading for motors  336