Page 18 - Industrial Power Engineering and Applications Handbook
P. 18

Introduction







         This book is split into five parts. A summary of each part   The text especially covers testing requirements and an
         follows.                                        introduction to quality assurance systems and applica-
                                                         tion of IS0 9001.
                                                         Special coverage of impulse testing of resin-rich formed
         Part I Selection, testing, controls             coils and their in-house testing requirements is given.
         and protection of electric motors

         This part deals with three- and single-phase ax. machines,   Part  II  Switchgear  assemblies  and
         and their protective switchgears. However, reference is   captive (emergency) power generation
         made to and comparisons drawn of a d.c. motor with an   (Including  instrument transformers  and  cable
         ax. motor,  to  assist a user  to make  a proper choice of   selection)
         machine.
          However simple a motor is, it requires careful handling
         to ensure optimum performance and long years of trouble-   The subjects covered aim at providing methods to form
         free operation. A small drive, failing while in operation,   specifications and then design a switchgear assembly for
         may bring the entire process to a halt.  One can visualize   all power distribution needs. lt also provides coverage of
         the  loss  of  production  that  can  result.  Power  plants,   draw-out  assemblies.  Establishing  the  fault  level  of  a
         chemicals, fertilizers, petrochemicals, paper and cement   system  is  described  including  the  electrodynamic  and
         mills all require careful selection of equipment to avoid   electromagnetic forces that arise.
         breakdown or malfunctioning during operation. Motors
         and their  controlgears are core components that require   Testing procedures are informative and elaborate.
         special attention:                              Seismic effects and earthquake engineering is covered
                                                         in this part to study the behaviour of an object under
          This part  deals  with  the specifications, performance,   seismic  conditions  and  its  suitability for  critical
          characteristics and behaviour of motors under different   installations. The formation of the earth and movements
          operating conditions, their application and selection.   of tectonic plates that cause earthquakes and volcanic
          It  also covers aspects such as shock loading, motors   eruptions are described.
          for hazardous locations and open transient conditions   Instrument transformers (CTs, class PS, CT,, VTs and
          in HT motors during a switching sequence.      CVTs etc.) form important components of a switchgear
          In  Chapter  12  a  detailed  analysis  is  made  of  all   assembly for measurement and protection. They are
          unfavourable operating conditions and their effect on   covered  for  their  specifications,  selection  and
          the  performance  of  the  motor  and its  protection  for   application.
          optimum utilization. The precautions also cover surge   Design of class PS CTs (special coverage) is provided.
          protection for HT motors. The details provided  cover   Captive  (emergency)  power  generation  covers  the
          the smallest-influence that a particular parameter can   application  of  a  diesel  generating  set,  its  starting,
          have on a machine.                             protection, synchronizing and load sharing. This forms
          This  part-also  deals with  static controls  and drives,   an  important  part  of  power  distribution  at  any
          soft starting  and  process  control  through  solid-state   installation to provide a standby  source of  supply.
          technology (phasor and field-oriented controls) using   The entire painting rocedure and effluent treatment is
          IGBTs as well as energy conservation.          covered for those in the field of  manufacturing  such
          There  is  special coverage of  fluid couplings for soft   assemblies.
          starting and speed control. A comparison between static   In an attempt to provide as much information on the
          drives and variable-speed fluid couplings is made.   related  subjects  as  possible  and  to  make  the  book
          Windmills (induction generators) as an unconventional   more complete for a project or a design engineer we
          energy source, vertical  hollow shaft motors and sub-   have provided data and tables on cables and described
          mersible pump sets, selection of belts for transmission   in  detail  the procedure for the  selection  of  the  type
          of load. the phenomenon of shaft currents are discussed.   and size of control and LT and HT power cables.
   13   14   15   16   17   18   19   20   21   22   23