188   20 Burns




               Examination of the barrel temperature readings will indicate if there are zones
               that are overheating. Often the zone may actually be overriding from the shear
               heating during screw recovery. If the zone is running over the set point but not
               actually calling for heat one of two possibilities exist:
               1. The shear created from the rotating screw is generating heat and higher tem-
                 perature than the set point and the barrel heaters are no longer being used to
                 control the barrel temperature at all. If this is the case look at reducing the
                 screw rotation speed to allow the screw to recover 2–3 seconds prior to mold
                 open, or examine the back pressure being applied to the screw.
               2. There is a remote possibility that the thermocouples have been installed in the
                 incorrect locations. This is more likely a potential cause if heaters or thermo-
                 couples had been recently replaced on the machine. If this is the case you will
                 see a zone that is running hot without calling for heat and another zone will be
                 running cold while calling for heat continuously. This is a good indicator that
                 the thermocouples have been cross wired.
                 IR photos can be used to discover hot spots in the nozzle as shown in Figure
                 20.4.






























               Figure 20.4  IR photo of nozzle looking for hot spots



               20.3.3.4„ Machine: Damaged Components
               Damaged components in the screw, barrel, check valve, end cap, nozzle, or tip can
               lead to areas of high shear and or buildup locations. The damaged components can