Page 307 - Solutions Manual to accompany Electric Machinery Fundamentals
P. 307

Since there are 60 coils in each phase and 8 turns per coil, all connected in series, there are 480 turns per
                 phase.  The resulting voltage is
                         V     2N  P k  p k d f e    2 480  turns  0.951   0.962    60     Hz  
                         V   117 , 061     


                 The phase voltage of this generator must be 13    8 .  kV  /   3   7967  V   , so the flux must be

                             7 967  V
                                     . 0  068   Wb
                             117,061

                 (b)  The machine’s winding factor is
                         k w   k  p k d    0.951 0.962    0  . 915






























































                                                           301