Page 97 - Machinery Component Maintenance
P. 97

80   Machinery  Component Maintenance and Repair


























          Figure 3-2. A photograph of a cambered and grooved surface of an airport runway. Note
          the degree of penetration between furrows as a low viscosity solution of epoxy adhesive in
          acetone is poured on and drained away from the surface (Courtesy of Adhesive Services
          Company).
































          Figure 3-3. Hairline curing cracks become visible as the solvent in Figure 3-2 evaporates
          from the surface (Courtesy of Adhesive Services Company).