Page 140 - Multidimensional Chromatography
P. 140

132                                     Multidimensional Chromatography

                            37. M.-C. Hennion, ‘Solid-phase extraction: method development, sorbents and coupling
                               with liquid chromatography’, J. Chromatogr. 856:3–54 (1999).
                            38. K. A.  Ramsteiner, ‘Systematic approach to column switching’, J. Chromatogr. 456:
                               3–20 (1988).
                            39. S. R. Villaseñor, ‘Matrix elimination in ion chromatography by  “heart-cut” column
                               switching techniques’, J. Chromatogr. 602:155–161 (1992).
                            40. S. R. Villaseñor, “Heart-cut” column switching techniques for the determination of an
                               aliphatic amine in an organic matrix and for low levels of sulfate in an anion matrix’,
                               J. Chromatogr. 671:11–14 (1994).
                            41. H. J. Cortes and L. D. Rothman, ‘Multidimensional high-performance liquid chro-
                               matography’ in Multidimensional Chromatography: Techniques and Applications, H. J.
                               Cortes (Ed.) Marcel Dekker, New York, Ch. 6, pp. 219–250 (1990).
                            42. A. Farjam, G. J. de Jong, R. W. Frei, U. A.  Th Brinkman, W. Haasnoot, A. R. M.
                               Hamers, R. Schilt and F. A. Huf, ‘Immunoaffinity pre-column for selective on-line sam-
                               ple pre-treatment in high performance liquid chromatography determination of
                               19–nortestosterone’, J. Chromatogr. 452:419–433 (1988).
                            43. W. Haasnoot, M. E. Ploum, R. J. A. Paulussen, R. Schilt and F. A. Huf, ‘Rapid determi-
                               nation of clenbuterol residues in urine by high performance liquid chromatography with
                               on-line automated sample processing using immunoaffinity chromatography’,
                               J. Chromatogr. 519:323–335 (1990).
                            44. A. Farjam, A. E. Brugman, A. Soldaat, P. Timmerman, H. Lingerman, G. J. de Jong,
                               R. W. Frei and U. A. Th Brinkman, ‘Immunoaffinity precolumn for selective sample
                               pretreatment in column liquid chromatography: immunoselective desorption’,
                               Chromatographia 31:469–477 (1991).
                            45. G. S. Rule, A. V. Mordehai and J. Henion, ‘Determination of carbofuran by on-line
                               immunoaffinity chromatography with coupled-column liquid chromatography/mass
                               spectrometry’, Anal. Chem. 66:230–235 (1994).
                            46. V. Pichon, L. Chen and M.-C. Hennion, ‘On-line preconcentration and liquid chromato-
                               graphic analysis of phenylurea pesticides in environmental water using a silica-based
                               immunosorbent’, Anal. Chim. Acta 311:429–436 (1995).
                            47. V. Pichon, L. Chen, M.-C. Hennion, R. Daniel, A. Martel, F. Le Goffic, J. Abian and
                               D. Barcelò, ‘Preparation and evaluation of immunosorbents for selective trace enrich-
                               ment of phenylurea and triazine herbicides in environmental waters’, Anal. Chem. 67:
                               2451–2460 (1995).
                            48. I. Ferrer, V. Pichon, M-C. Hennion and D. Barcelò, ‘Automated sample preparation with
                               extraction columns by means of anti-isoproturon immunosorbents for the determination
                               of phenylurea herbicides in water followed by liquid chromatography–diode array
                               detection and liquid chromatography–atmospheric pressure chemical ionization mass
                               spectrometry’, J. Chromatogr. 777:91–98 (1997).
                            49. N. C. van de Merbel, M. Stenberg, R. Öste, G. Marko-Varga, L. Gorton, H. Lingeman
                               and U. A. Th Brinkman, ‘Determination of D- and L-amino acids in biological samples
                               by two-dimensional column liquid chromatography’, Chromatographia 41:6–14
                               (1995).
                            50. M.  Tanaka and H. Yamazaki, ‘Direct determination of pantoprazole enantiomers in
                               human serum by reversed-phase high performance liquid chromatography using a cellu-
                               lose-based chiral stationary phase and column-switching system as a sample cleanup
                               procedure’, Anal. Chem. 68: 1513–1516 (1996).
                            51. P. R. Baker, M. A. J. Bayliss and D. Wilkinson, ‘Determination of a major metabolite of
                               tipredane in rat urine by high performance liquid chromatography with column switch-
                               ing’, J. Chromatogr. 694:193–198 (1997).
   135   136   137   138   139   140   141   142   143   144   145