Page 240 - Practical Machinery Management for Process Plants Major Process Equipment Maintenance and Repair
P. 240

222    Major Process Equipment Maintenance and Repair

                        9.  Turbocharger-Check  Cooling  Wter AT  Monitor  temperature
                           rise of cooling water across the turbocharger and record.
                       10.  Service Auxiliary Belts and Bearings. This means that belts are
                           tightened  properly,  all bearings greased  or  lubricated,  and  all
                           sheaves are properly aligned.
                       11.  Change Oil Filter-Engine.
                       12.  Check Force Feed Lube System. Disconnect tubing at each lubrica-
                           tion point and confirm that lube oil is reaching that point.
                       13.  Change and Clean Inlet Air Filter
                             Oil Bath  Type. Change oil and clean reservoir.  If  differential
                            pressure remains excessive, steam clean the mesh pads.
                            Dry Tpe. Change out filter elements.
                       14. Run Jacket mrer Analysis. If a laboratory is available, complete
                           chromate analysis and determine pH of water. If a laboratory is
                           not available, take quart sample of water to the nearest commer-
                           cial laboratory for analysis.