222 Major Process Equipment Maintenance and Repair
9. Turbocharger-Check Cooling Wter AT Monitor temperature
rise of cooling water across the turbocharger and record.
10. Service Auxiliary Belts and Bearings. This means that belts are
tightened properly, all bearings greased or lubricated, and all
sheaves are properly aligned.
11. Change Oil Filter-Engine.
12. Check Force Feed Lube System. Disconnect tubing at each lubrica-
tion point and confirm that lube oil is reaching that point.
13. Change and Clean Inlet Air Filter
Oil Bath Type. Change oil and clean reservoir. If differential
pressure remains excessive, steam clean the mesh pads.
Dry Tpe. Change out filter elements.
14. Run Jacket mrer Analysis. If a laboratory is available, complete
chromate analysis and determine pH of water. If a laboratory is
not available, take quart sample of water to the nearest commer-
cial laboratory for analysis.