Page 383 - Practical Machinery Management for Process Plants Major Process Equipment Maintenance and Repair
P. 383

362  Mujor Process &u@rnent  Maintenance and Repair


                                                  Table 8-5
                                  Normal Oil Pressure and Temperature Ranges
                                  for Condensing and Noncondensing Turbines



















                       Notes
                       1.  These guidelines are not intended to supersede the original manufacturer’s rec-
                          ommendations.  It is the intent to indicate the general service requirements and
                          leave the particular recomrnendatlons  to the OEM.
                       2.  Column “A” provides the general guidelines for turbines lubricated by a turbine
                          shaft driven pump or by the driven machine.
                       3. Column “B” shows the acceptable general guidelines for turbines lubricated from
                          gear oil systems.

                          troubleshooting guide in Volume 2 for possible causes and correc-
                          tive actions for abnormal conditions.
                       6. When the turbine is thoroughly warmed up and operation is deter-
                          mined to be satisfactory, check that all drain valves are open and
                          gradually increase the speed. Increase the speed with the governor
                          speed adjustment until the turbine is operating at the rated speed
                          shown on the turbine nameplate. (Adjust the governor as outlined in
                          Governor Operation, Chapter 11.)  Continue to check the turbine
                          for unusual noises, rubbing, vibration or other signs of distress. Do
                          not continue to operate if any of these conditions exist. See the trou-
                          bleshooting guide in Volume 2 for possible causes and corrective
                          actions for abnormal operating conditions.

                          Note: If the turbine is pressure lubricated, the oil pressure should
                                be 7 to 9 psig (0.5 to 0.6 bar).
                       7.  Check the overspeed trip by overcoming the governor to actuate the
                          overspeed trip mechanism.  Refer to Governor Operation for spe-
                          cific details on overspeeding the turbine.
   378   379   380   381   382   383   384   385   386   387   388