Page 260 - Principles of Applied Reservoir Simulation 2E
P. 260

Part IV:  WINB4D  User's  Manual  245



                         24.2 Seismic Velocity Parameters

       24.2.1 Moduli and Grain Densities


        1,   Heading    Up to  80 characters.

       2     KKB, KKG, KMU, KRHO
             KKB        Control code for input of the frame bulk modulus
                        (evacuated porous  rock).
             KKG        Control  code  for input of the grain  bulk modulus  (solid
                        matrix material).
             KMU        Control  code for input of the shear modulus  (evacuated
                        porous  rock).
             KRHO       Control  code for input of the grain density (solid  matrix
                        material).



         Code    Value                      Meaning
                   -1    Frame bulk moduli are the same for all blocks in the grid.
                         Read  only one value.
                   0     A constant  value of frame bulk modulus is read for each
         KKB             layer  in the  grid;  each  layer  may  have  a  different,  but
                         constant  value.  Read KK  values.
                   1     Frame bulk moduli are read  for each  block  in the  grid.
                         Read  II  x JJ  x KK values.
                   -1    Grain bulk moduli are the same for all blocks in the grid.
                         Read only one value.
                   0     A constant value of grain bulk modulus is read  for each
         KKG             layer  in the  grid;  each  layer may  have  a  different,  but
                         constant value. Read KK values.
                   1     Grain  bulk  moduli are  read  for  each  block  in the  grid.
                         Read II  x JJ  x KK  values.
   255   256   257   258   259   260   261   262   263   264   265