Page 340 - Reciprocating Compressors Operation Maintenance
P. 340

Troubleshooting  Compressor Problems  325


           This procedure also applies to the discharge valves, which, of course, will
         be  at a considerably higher temperature, 350°-375°F on  a  100 psi single-
         stage  air  compressor.  In  any event, it is  recommended  practice  to  look  for
         any valves exhibiting cover temperatures more than  15°F higher than usual,




           Multistage compressors  are designed  so that the amount of  work per-
         formed  per  stage  is exactly equal.  In other  words, a two-stage  100 BHP
         compressor will require a 50 BHP per stage.
           The correct  pressure ratio across  each stage is determined  by  formulas
         employing absolute pressures:

           2 Stage:  2I&-    3 Stage:  3 p-
                5
                    1JP,             ^Pi
           Improper  interstage  pressures  can  cause  problems  with  rod  loads,
         capacity, vibration, etc.
           On  multistage compressors,  the interstage  pressure  should  be  checked
         even before valve temperature readings are acquired. See page 25.

         Low  INTERSTAGE  PRESSURE


           On  multistage compressors,  intercooler  pressure  deviations  will  point
         to the cylinder in which a problem  is occurring. When a lower than nor-
         mal interstage pressure  is noted, a problem  in the preceding cylinder, that
         is,  first  stage  of a two-stage  compressor  exists. If the interstage  pressure
         is  low  when  the  compressor  is  loaded  and  remains  steady  when
         unloaded,  the  fault  is  in  the  suction  valves  of  the  preceding  cylinder
         (first-stage  of  a  2-stage  compressor).  Should  the  pressure  drop  to  zero,
         the discharge valves of the preceding cylinder are at  fault.

         HIGH  INTERSTAGE  PRESSURE


           A  higher  than  normal intercooler  pressure  indicates  problems  in  the
         succeeding  cylinder, that  is,  second  stage  of  a  two-stage  compressor.
         Should  the  pressure  be  higher  than  normal  when  the  compressor  is
         loaded,  the suction  valves of the  succeeding cylinder  are the problem. If
         the intercooler pressure is higher when unloaded, the discharge valves in
         the  succeeding  cylinder are  at  fault.  If  interstage  pressure  becomes  too
         high, the safety  relief valve will blow.
   335   336   337   338   339   340   341   342   343   344   345