106   INTRODUCTION TO SOLAR POWER SYSTEM DESIGN


                  Isc (short-circuit current)              5.30 A

                  Imp (maximum peak current)               4.90 A
                  Maximum system voltage (V dc)            600 V


                Input Assumptions

                  Inverter model                           75 kW, 480 V ac

                  PV module                                SolarWorld AG SW 175 mono
                  Temperature scale                        Fahrenheit
                  Minimum ambient temperature              25
                  Maximum ambient temperature              90

                  Mounting method                          Ground mount/tilt
                  CEC or STC module power                  STC (standard test condition)
                  Optimum array derating coefficient        0.8

                  Voltage drop in array wiring             1.5


                Resulting Design Parameters

                  Ideal number of series modules (strings)  11
                  Nominal Vmp w/11 series modules (V dc)   387

                  Minimum number of modules                11
                  Maximum number of modules                11
                  Maximum allowed number of modules        560
                  Maximum number of series of module strings  48



                Inverter Output

                  Continuous ac power rating               75 kW
                  AC voltage (V ac line—line)              480 V, 3 phase
                  Nominal ac output current                91 A

                  Maximum fault ac output current/phase    115 A
                  Minimum dc input voltage                 330 V dc
                  Maximum dc input voltage                 600 V dc
   131   132   133   134   135   136   137   138   139   140   141