EXAMPLE OF TYPICAL SOLAR POWER SYSTEM DESIGN  121


               translates into 36,000 W/day. Figure 5.1 depicts a residential roof-mount PV array lay-
               out, in Palm Springs, California and Figure 5.2 the solar power system schematic
               wiring diagram.
                  Since the average daily insolation in southern California is about 5.5 hours, the
               approximate solar power system required to satisfy the daily demand load should be
               approximately 6000 W. Occupancies that are not fully inhabited throughout the day
               may require a somewhat smaller system.
                  In general, an average 8 hours of habitation time should be used for sizing the solar
               power system, which in this example would yield a total daily power demand of
               24,000 Wh, which in turn translates into a 4000-W solar power system.



















































         Figure 5.2   Solar power system schematic wiring diagram, Reed residence, Palm
         Springs, California.
   146   147   148   149   150   151   152   153   154   155   156