Brockenbrough_Ch05.qxd  9/29/05  5:12 PM  Page 5.21



                                                    CRITERIA FOR BUILDING DESIGN


                                                                              CRITERIA FOR BUILDING DESIGN  5.21

                                  For noncompact flange sections,
                                                                        λλ  pf  
                                                                           −
                                                           F =  F − (.03 F )  − λ                  (5.65)
                                                                       y 
                                                                y
                                                            cr
                                                                       λ rf  pf   
                                  For slender flange sections,
                                                                 F =  09 .  Ek c                      (5.66)
                                                                  cr
                                                                     b 2 )
                                                                     (/  t  f  2
                                                                      f
                                  where
                                                        k =  4     and   0.35  ≤  k ≤ 076             (5.67)
                                                                                  .
                                                        c
                                                                               c
                                                             /
                                                            ht w
                                  and the λ slenderness terms are as defined with Eq. (5.54).
                                    For tension flange yielding, when S xt ≥ S xc , the limit state of tension flange yielding does not
                                  apply. When S xt < S xc ,
                                                                                                      (5.68)
                                                                  M n = F y S xt
                                  where S xc is the section modulus about the x axis referred to the compression flange and S xt is the
                                  section modulus about the x axis referred to the tension flange.
                      5.5.4 I-Shaped Members and Channels—Minor Axis Bending
                                  The nominal flexural strength M n for I-shaped members and channels subjected to bending about the
                                  minor axis is the lower of two limit states: yielding (plastic moment) and flange local buckling.
                                    For yielding (plastic moment),
                                                                                                      (5.69)
                                                             M n = M p = F y Z x ≤ 1.6F y S y
                                    For flange local buckling, three cases may arise. When the flanges are compact, this limit state
                                  does not apply. When the flanges are noncompact,
                                                                           λλ  pf  
                                                                              −
                                                       M =  M − ( M − .07 F S )                    (5.70)
                                                                        y y 
                                                                   p
                                                              p
                                                         n
                                                                          λ rf  − λ pf   
                                  When the flanges are classified as slender,
                                                                                                      (5.71)
                                                                M n = F cr S y
                                                                       .
                                                                 F =  069 E                           (5.72)
                                                                 cr
                                                                     b 2 )
                                                                     (/  t  f  2
                                                                      f
                                  where λ= b/t = flange width-to-thickness ratio
                                       λ pf = limiting slenderness for a compact flange (Art. 5.1.5)
                                       λ rf = limiting slenderness for a noncompact flange (Art. 5.1.5)
                                       S y = minimum section modulus about y axis
                      5.5.5 Square and Rectangular HSS and Box-Shaped Members
                                  This article applies to square and rectangular hollow structural sections (HSS), and doubly symmet-
                                  ric box-shaped members bent about either axis. The sections may have compact or noncompact webs,
                                  and compact, noncompact, or slender flanges (see Art. 5.1.5). The nominal flexural strength, M n , is the
                                  lower of three limit states: yielding (plastic moment), flange local buckling, and web local buckling.



                              Downloaded from Digital Engineering Library @ McGraw-Hill (www.digitalengineeringlibrary.com)