Page 275 - Structural Steel Designers Handbook AISC, AASHTO, AISI, ASTM, and ASCE-07 Design Standards
P. 275

Brockenbrough_Ch05.qxd  9/29/05  5:12 PM  Page 5.55



                                                    CRITERIA FOR BUILDING DESIGN


                                                                              CRITERIA FOR BUILDING DESIGN  5.55

                                  where F yf = specified minimum yield stress of the flange, ksi (MPa), and t f = thickness of the loaded
                                  flange, in (mm). When the concentrated force to be resisted is applied at a distance from the mem-
                                  ber end less than 10t f , R n must be reduced by 50%. If the length of loading across the member flange
                                  is less than 0.15b f , where b f is the member flange width, Eq. (5.162) need not be checked. Use a pair
                                  of transverse stiffeners if the available strength is inadequate.

                                  2. Local Web Yielding.  This limit state applies to single-concentrated forces, tension or compres-
                                  sion, and both components of double-concentrated forces. The available strength for the limit state
                                  of local web yielding is determined using φ = 1.00 (LRFD) and Ω = 1.50 (ASD). Use a pair of trans-
                                  verse stiffeners or a doubler plate if the available strength is inadequate.
                                    When the concentrated force to be resisted is applied at a distance from the member end greater
                                  than the depth of the member d, the nominal strength, R n , is
                                                                                                     (5.163)
                                                               R n = (5k + N)F yw t w
                                    When the concentrated force to be resisted is applied at a distance from the member end less than
                                  or equal to the depth of the member d,
                                                                                                     (5.164)
                                                               R n = (2.5k + N)F yw t w
                                  where F yw = specified minimum yield stress of the web, ksi (MPa)
                                        N = length of bearing (not less than k for end beam reactions), in (mm)
                                         k = distance from outer face of the flange to the web toe of the fillet, in (mm)
                                        t w = web thickness, in (mm)

                                  3. Local Web Crippling.  This limit state applies to compressive single-concentrated forces or the
                                  compressive component of double-concentrated forces. The available strength for the limit state of
                                  local web crippling is determined using φ= 0.75 (LRFD) and Ω = 2.00 (ASD). If the available
                                  strength is inadequate, use a transverse stiffener, a pair of transverse stiffeners, or a doubler plate
                                  extending at least one-half the depth of the web.
                                    When the concentrated compressive force to be resisted is applied at a distance from the member
                                  end greater than or equal to d/2, the nominal strength R n is

                                                                    N   t  15 .    EF t
                                                                  +
                                                               2
                                                        R = 080 t 13     w      yw  f           (5.165)
                                                            .
                                                               w
                                                         n
                                                                     d    t      t w
                                                                         f
                                    When the concentrated compressive force to be resisted is applied at a distance from the member
                                  end less than d/2, the nominal strength R n depends on the N/d ratio.
                                    If N/d ≤ 0.2,
                                                                     N   t  15 .    EF t
                                                               2
                                                                  +
                                                            .
                                                        R = 040 t 13     w      yw  f           (5.166)
                                                               w
                                                         n
                                                                   d    t      t w
                                                                         f
                                    If N/d > 0.2,
                                                                          t   w  15 .    EF t
                                                             2
                                                      R = 040 t 1 +   4 N  − 02 .         yw  f  (5.167)
                                                          .
                                                             w
                                                       n
                                                                   d    t   f      t w
                                  where d = overall depth of the member, in (mm), and t f = flange thickness, in (mm).
                                  4. Web Sidesway Buckling.  This limit state applies to compressive single-concentrated forces act-
                                  ing on members where relative lateral movement between the loaded compression flange and the ten-
                                  sion flange is not restrained at the point of application of the concentrated force. The available
                              Downloaded from Digital Engineering Library @ McGraw-Hill (www.digitalengineeringlibrary.com)
                                         Copyright © 2004 The McGraw-Hill Companies. All rights reserved.
                                          Any use is subject to the Terms of Use as given at the website.
   270   271   272   273   274   275   276   277   278   279   280