Page 272 -
P. 272

The Practical Pumping Handbook                               ..............................................


                      On-Plot
                      Process   Off- Plot             Pressure
                      Reference  Transfer  &  Temperature  Range   Material  See
      Service         Plant     Loading   Range  (~   (psig)   Class   Note

      Noncorrosive    X         X         45-700      All     S-4      7
        hydrocarbons,
        e.g.  catalytic
        reformate,
        ixomataxate,
        desulfurized oils.
      Xylene, toluene,   X      X         <450        All     S-1
        acetone,
        benzene furfural,
        MEK,  cumene
      Sodium carbonate,  X      X         <350        All     I-1
        doctor solution
      Caustic  (sodium          X         <210        All     S-1      8
        hydroxide,
        concentration                     >210        All              9
        of < 20%
      Seawater        X         X          <200       All              10
      MEA,  DEA,  TEA   X       X          <250       All     S-1
         -  stock solutions
      DEA,  TEA -  lean   X     X          <250       All     S-1
         solutions
      MEA-lean  solution  X     X          175-300    All     S-9
         (CO2  only)
      MEA-lean  solution  X     X          175-300    All              8,11
         (CO2  and  H2S)
      MEA,  DEA,  TEA   X       X         <175        All     S-1      8
        -  rich solutions
      Sulfuric Acid
        concentrations
        85%           X         X         <100        All     S-1      6
        85% -  15%    X         X         < 100       All     A-8      6
        15%-  1%      X         X         < 100       All     A-8      6
        1%            X         X         <450        All     A-8      6
      Hydrofluoric  acid   X    X         < 100       All     S-9      6
        concentration
        of>96%






          250
   267   268   269   270   271   272   273   274   275   276   277