Page 272 -
P. 272
The Practical Pumping Handbook ..............................................
On-Plot
Process Off- Plot Pressure
Reference Transfer & Temperature Range Material See
Service Plant Loading Range (~ (psig) Class Note
Noncorrosive X X 45-700 All S-4 7
hydrocarbons,
e.g. catalytic
reformate,
ixomataxate,
desulfurized oils.
Xylene, toluene, X X <450 All S-1
acetone,
benzene furfural,
MEK, cumene
Sodium carbonate, X X <350 All I-1
doctor solution
Caustic (sodium X <210 All S-1 8
hydroxide,
concentration >210 All 9
of < 20%
Seawater X X <200 All 10
MEA, DEA, TEA X X <250 All S-1
- stock solutions
DEA, TEA - lean X X <250 All S-1
solutions
MEA-lean solution X X 175-300 All S-9
(CO2 only)
MEA-lean solution X X 175-300 All 8,11
(CO2 and H2S)
MEA, DEA, TEA X X <175 All S-1 8
- rich solutions
Sulfuric Acid
concentrations
85% X X <100 All S-1 6
85% - 15% X X < 100 All A-8 6
15%- 1% X X < 100 All A-8 6
1% X X <450 All A-8 6
Hydrofluoric acid X X < 100 All S-9 6
concentration
of>96%
250