Page 146 - Welding of Aluminium and its Alloys
P. 146

MIG welding    131



















                                                              (a)































                                                                        (b)
                    7.14 (a) MIG, argon shielded, two pass, double sided, 12mm thick, flat
                    position. (b) MIG, argon shielded, 15mm leg length fillet, 12mm thick
                    plate, horizontal-vertical.



             bead. The wider bead requires less critical positioning of the arc and assists
             in avoiding missed edge and lack of penetration-type defects. The hotter,
             slower cooling weld pool also allows hydrogen to diffuse from the molten
             weld metal, making this a method that may be used to reduce the amount
             of porosity. The increased heat also enables faster welding speeds to be
   141   142   143   144   145   146   147   148   149   150   151