Page 188 - Wastewater Solids Incineration Systems
P. 188
Emission Control and Monitoring 155
FIGURE 7.8 A multiple Venturi scrubber (courtesy of Envirocare International, Inc.,
American Canyon, CA).
be accommodated by the multistage centrifugal blower used on a fluid bed inciner-
ator. (Many fluid bed incinerator facilities in England and Europe have waste heat
boilers that necessitate use of an induced draft fan.) Another disadvantage of the Ven-
turi scrubber is erosion of throat section and Venturi damper from high-velocity par-
ticles. Most newer Venturi scrubbers have throat sections lined with silicon carbide
tiles to mitigate the erosive effect of particulate matter.