4-48   WATER AND WASTEWATER ENGINEERING

                                  c. Well protection requirements
                                     (1) Casing
                                    (2) Grouting
                                    (3) Disinfection
                                    (4) Well house specifications

                                  d. Pump details
                                     (1) Capacity
                                    (2) Select a candidate pump
                                    (3) Specify the number of stages and NPSH

                                   4-23.   Your firm has been retained to develop plans for a well system for the village of
                                     Waffle. Using the design elements listed above Problem 4-23 and the following data,
                                     design the well system.
                                     a. Population: 250
                                     b. Demand: 570 Lpcd
                                     c.  Water is to be supplied from wells. No treatment will be provided.
                                     d. Top of reservoir is 66.0 m above ground level
                                     e.  Friction losses     minor losses in piping from well to top of reservoir     0.5 m
                                     f.  Water supply is to be chlorinated, but no other treatment will be provided.


                                       TEST BORING RESULTS,   WAFFLE

                                         Bore hole no. 2 (surface elevation: 335 m)
                                         Strata          Thickness, m       Depth to bottom of strata, m
                                         Soil (Rubicon)       1.2                  1.2
                                        Sand                13.1                  14.3
                                        Clay, red            6.1                  20.4
                                        Galena dolomite        44.8               65.2
                                        Maquoketa shale        39.0              104.2
                                        Someko sand         41.9                 146.1
                                        Eau Claire shale       Boring terminated at 146.1 m

                                     An analysis of the water indicates that it is not corrosive.
                                         Grain size analysis of Someko sand

                                                   U.S. sieve no.       Wt. % retained
                                                       8                   2
                                                     12                    1
                                                     16                    2
                                                     20                   15
                                                      30                   35
                                                     40                    33
                                                      50                   6
                                                     70                    2
                                                    100                    2
                                                   PAN                     2