Page 83 - Quick Guide to Welding and Weld Inspection by S.E. Hughes, Clifford Matthews
P. 83

A Quick Guide to Welding and Weld Inspection


































                      Figure 6.1 Liquid penetrant testing

            technique that is often used to confirm visual uncertainties.
            Viewing is done under good lighting conditions of 1000 lux
            (100 ft candles).
              Typical colour contrast penetrants used are solvent
            removable,  post-emulsifiable  or  water  washable.
            Fluorescent penetrants can also be used in solvent remov-
            able, post-emulsifiable or water washable form but are
            viewed under ultraviolet (UV) light and tend to be more
            sensitive than the colour contrast methods. Viewing is done



                                   68


               Woodhead Publishing Ltd – A Quick Guide to Welding and Weld Inspection
            Data Standards Ltd, Frome, Somerset – 17/9/200906QG Welding chap6.3d Page 68 of 87
   78   79   80   81   82   83   84   85   86   87   88