Page 219 - Advanced Gas Turbine Cycles
P. 219

Chapter 9.  The gas turbine as a cogeneration (combined hear and power) plant   181

       Headwork ratio                       1.7
       Water supply temperature (TB)        150°C
       Water return temperature (TA)        128°C
       Exhaust gas flow (MG)                15.3 kgls
       Water flow (Mw)                      150 t/h
       For WHR operation                   EUF = 0.73       0.4 X 0.9
         (&G  = I .7,  vc = 0.4,  vc = 0.9)   FESRZ1-                    = 0.155
                                                       0.27(0.9 + 1.7 X 0.4)
          A full description of the economics of operating this plant over a complete year is given
       by Horlock  [I].



       References

       [I ]  Horlock, J.H. (1997). Cogeneration-Combined Heat and Power Plants, 2nd edn, Krieger, Malabar, Florida.
       [2]  Porter,  R.W.  and  Mastanaiah,  K.  (1 982),  Thermal-economics  analysis  of  heat-matched  industrial
          cogeneration systems, Energy 7(2). 171 - 187.