Page 211 - Advances in Forensic Applications of Mass Spectrometry - Jehuda Yinon
P. 211
1522_book.fm Page 191 Thursday, November 13, 2003 9:58 AM
minutes
17.5
15.0
12.5
10.0 A 1-ml spike of gasoline standard (top) was added to previously burned nylon carpet and the heated headspace above
7.5
5.0 the burned debris was extracted using an ACS (bottom) and analyzed using GC/MS.
© 2004 by CRC Press LLC
2.5
kCounts 350 300 250 200 150 100 50 0 100 kCounts 75 50 25 0
Figure 5.5