Machine-Train Monitoring Parameters   91






































                            Figure 5–9 Horizontal, reciprocating compressor.





















                     Figure 5–10 Screw compressor—steady-state applications only.

            The gear set should be monitored for axial thrusting. Because of the compressor’s sen-
            sitivity to process instability, the gears are subjected to extreme variations in induced
            axial loading. Coupled with the helical gear’s normal tendency to thrust, the change
            in axial vibration is an early indicator of incipient problems.