Page 127 - Analytical method for food addtives
P. 127

E220–8: Sulphites  77


               infrared spectrometry’, Perez-Ponce A, Garrigues S, de la Guardia M. Quimica Analitica
               (2000) 19(3), 151–158.
            22 ‘The determination of total SO  in grape juice. A comparison among five methods’,
                                     2
               Ferrarini R, Celotti E, Versari A, Galassi S. Food Additives and Contaminants (2000)
               17(12), 973–977.
            23 Validation of Enforcement Methods Service (VEMS) Method Ref 0158: Gravimetric
               Method for Sulfur Dioxide in Meat Products.
            24 Validation of Enforcement Methods Service (VEMS) Method Ref 0360:  Titration
               Method for Sulfur Dioxide in Foods, General.
            25 Validation of Enforcement Methods Service (VEMS) Method Ref 0308:  Titration
               Method for Sulfur Dioxide in Foods, General.
            26 Validation of Enforcement Methods Service (VEMS) Method Ref 0246:  Titration
               Method for Sulfur Dioxide in Foods, General.
            27 ‘Dietary intake exposure to sulfites in Italy – analytical determination of sulfite-
               containing foods and their combination into standard meals for adults and children’,
               Leclerq C, Molinaro M G, Piccinelli R, Baldini M, Arcella D, Stacchini P.  Food
               Additives and Contaminants (2000) 17, 979–989.



            8.5  Appendix: method procedure summaries

            Analysis of foodstuffs with sulphite content ≥≥ ≥≥ ≥10 mg/kg using optimised
            Monier–Williams method 2

            Scope
            Distillation method for determination of sulphite content, expressed as sulphur
            dioxide. The method is applicable in the presence of other volatile sulphur
            compounds. It is not applicable to cabbage, dried garlic, dried onions, ginger, leeks
            and soy proteins.

            Principle
            Free sulphite plus reproducible portion of bound sulphites (such as carbonyl
            addition products) in foods are measured. The test portion is heated with a
            refluxing solution of hydrochloric acid to convert sulphite to sulphur dioxide. A
            stream of nitrogen is introduced below the surface of the refluxing solution to
            sweep sulphur dioxide through water-cooled condenser and via a bubbler attached
            to the condenser, into the hydrogen peroxide solution, where sulphur dioxide is
            oxidised to sulphuric acid. The generated sulphuric acid is titrated with standard-
            ised sodium hydroxide solution. The sulphite content is directly related to the
            generated sulphuric acid (see ).
                                   3,4
            Procedure
            Sample preparation and analysis should be carried out as quickly as possible to
            avoid loss of labile forms of sulphite.
              (Note: to become familiar and proficient with the method before routine use, it
            is recommended that food test portions containing known amounts of sulphite are
            analysed. The analysis should be performed in a manner that precludes any loss of
   122   123   124   125   126   127   128   129   130   131   132