Page 161 - Analytical method for food addtives
P. 161

106  Analytical methods for food additives


              Repeatability
              The absolute difference between two single test results found on identical test
              material by one operator using the same apparatus within the shortest feasible time
              interval will exceed the repeatability limit r in not more than 5  % of the cases.
                The values are:
                                          –
                     Nitrite  corned beef (NO ) mean =  38.9 mg/kg r = 4.4 mg/kg
                                          2
              Reproducibility
              The absolute difference between two single test results on identical test material
              reported by two laboratories will exceed the reproducibility limit R in not more
              than 5 % of the cases.
                The values are:
                     Nitrite  corned beef (NO )  mean = 38.9 mg/kg  r = 10.3 mg/kg
                                          –
                                          2
              (For further information on this method see DD ENV 12014-4:1998.)



              9.6  Appendix 2: method procedure summaries (milk and
              milk products – BS EN ISO 14673)

              Method using cadmium reduction and spectrometry 2

              Preparation of test sample: dried milk and dried whey
              Transfer the test sample to a sample container of capacity about twice the volume
              of the test sample. Close the container immediately. Mix the test sample thoroughly
              by repeatedly shaking and inverting the container.

              Preparation of test sample: caseins and caseinates
              Thoroughly mix the test sample, if necessary after transferring all of it to a sample
              container of suitable capacity, by repeatedly shaking and inverting the container.
              Transfer 50 g of the test sample to the test sieve. If the 50 g portion directly passes,
              or nearly completely passes the sieve, pass the whole mixed test sample through
              the sieve. If the test sample does not pass completely through the sieve, use the
              grinding device to achieve that condition. Immediately transfer all the sieved test
              sample to the sample container and mix thoroughly in the closed container. During
              these operations, take precautions to avoid any change in the water content of the
              product.
                After the test sample has been prepared, proceed with the determination as soon
              as possible.
              Preparation of test sample: cheese
              Prior to analysis, remove the rind or mouldy surface layer of the test sample so as
              to provide a test sample representative of the cheese as it is usually consumed.
   156   157   158   159   160   161   162   163   164   165   166