66131_Ludwig_CH10H-J  5/30/2001 4:47 PM  Page 278










                       278                       Applied Process Design for Chemical and Petrochemical Plants

                                   V   vapor rate, lb/hr; also, used as molecular             mass rate of flow of condensate from lowest
                                       volume for component in diffusivity equa-             point on condensing surface divided by
                                       tion; or, linear velocity, ft/sec.                    breadth (unit perimeter), lb/(hr)(ft).
                                   V f   superficial flooding velocity of vapor, ft/sec.    = acceleration loss group, dimensionless; see
                                 V max   maximum vapor velocity in exit from                 Equation 10-181.
                                       reboiler, m/sec.                                       difference.
                                  V RB   vapor formed in reboiler, lb/hr.          ( t/ p) s   slope of vapor pressure curve.
                                   v   tube-side velocity, ft/sec; or, ft/hr.                 emissivity of a surface, ratio of total rate at
                                   v i   specific volume of fluid at inlet to reboiler,      which a gray surface emits radiation to the
                                        3
                                       ft /lb.                                               total rate at which a black body at the same
                                   v o   specific volume of fluid at outlet of reboiler,     temperature would emit radiation of all wave
                                        3
                                       ft /lb.                                               lengths, dimensionless; or, emissivity of the
                                   v s   superficial vapor velocity, usually, ft/sec.        outside surface of insulated or bare pipe.
                                   W   mass rate of flow, lb/hr condensate for con-      
    fin width at fin base, ft.
                                       densers; or, lb/sec; or, width of air-cooled        f   fin efficiency, fraction.
                                       exchanger, ft.                                     w   e f , weighted fin efficiency, fraction.
                                  W    flow rate, lb/sec.                                     tube taper angle (to horizontal), degrees.
                                                                                          2
                                  W    tube loading for condensing, lb/hr (ft of             effective average (two-phase)/liquid phase
                                       finned tube length).                                  pressure drop ratio corresponding to effec-
                                  W s   shaft work done by system, ft liquid.                tive average vaporization.
                                  W T   total vapor condensed in 1 tube, lb/hr; or,           latent heat of vaporization, Btu/lb.
                                       total mass flow rate, lb/sec.                          viscosity of fluid, lb/(hr)(ft); or, centipoise
                                   w   weight rate of fluid flow per tube,                   (as specified); or, viscosity at the caloric tem-
                                       lb/hr/tube; or, rate of condensation per              perature, lb/(ft)(hr).
                                       tube from lowest point of vertical tube(s),            viscosity of fluid at film temperature, lb/
                                       lb/(hr)(tube); or,   fin height, in.                  (hr)(ft)   (centipoise)   2.42   lb/(hr)(ft).
                                   X   N Re /1000.                                           viscosity, centipoise.
                                  X tt   correlating parameter, dimensionless for         f     absolute viscosity, lb/sec (ft)   (centipoise)
                                       turbulent-turbulent flow mechanism, Figure            (0.000672).
                                       10-113.                                             s   viscosity of fluid at film temperature of heat
                                   x   vapor quality in fluid, weight fraction, nucle-       transfer surface, lb/(hr)(ft).
                                       ate boiling; or distance film has fallen; or,      w   viscosity of fluid at wall temperature,
                                       weight fraction of vapor or gas, dimension-           lb/(hr)(ft); or, centipoise.
                                       less.                                                  3.1416.
                                                                                                       3
                                   x 2   height of liquid level in column above               density, lb/ft .
                                       reboiler bottom tubesheet, ft.                      t    d o for vertical tube perimeter, ft.
                                   x c   distance from top (effective) of tube, ft.       tp   effective average two-phase density, lb.ft 3
                                                                                                                           3
                                   y   mol vol % noncondensables in bulk stream.          tph   homogeneous two-phase density, kg/m .
                                   Z   distance or length, or vertical height, ft or          surface tension, lb/ft; or, dynes/cm as speci-
                                       in. as consistent; or, viscosity at flowing tem-      fied.
                                                                                                                      2
                                       perature, centipoise. (Used by permission:             surface tension of liquid, Btu/ft ; or,
                                                                                                                        2
                                                                                                                7
                                       Brown Fintube Company.)                               (dynes/cm)(0.88   10 )   Btu/ft .
                                  Z sp   height of individual spray zone, ft.                 surface tension of liquid, dynes/cm.
                                   Z   height (vertical) of driving leg for thermal    s or      Stefan-Boltzmann constant, 0.173 10  8
                                                                                                           4
                                                                                                      2
                                       circulation, ft.                                      Btu/(hr)(ft )(°R) .
                                                                                              constant, Gilmour boiling equation; or, sur-
                                          Greek Symbols                                      face condition factor, Equation 10-140; or,
                                                                                             tube density coefficient, Table 10-27.
                                                                                         –
                                   	    constant, Gilmour boiling equation; or, tube         average value of  .
                                                                                         –
                                       layout angle, degree   coefficient of ther-           physical property factor; or, parameter for
                                       mal expansion of fluid, %/°F; or, correction          two-phase flow, dimensionless.
                                       factor for convective heat transfer, dimen-        p     physical property factor for shell-side heat
                                       sionless; or, correction factor for nucleate          transfer.
                                       boiling, dimensionless; or, Ackerman cor-           s   ( /  w ) 0.14 , subscript  w refers to wall
                                       rection factor, dimensionless.                        condition.
                                   
    coefficient of expansion   1/T r , with T r in        maximum flux physical property factor,
                                                                                                   3
                                       °Rankine   °F   460.                                  Btu/(ft )(hr), Equation 10-149.
   314   315   316   317   318   319   320   321   322   323   324