Page 316 - Applied Process Design For Chemical And Petrochemical Plants Volume III
P. 316

66131_Ludwig_CH10H-J  5/30/2001 4:47 PM  Page 275










                                                                    Heat Transfer                                          275

                                 h c   heat transfer coefficient for outside of coil,  K 1 , K 2 , K 3,  K 4   constants in tube count equation.
                                              2
                                      Btu/(hr)(ft )(°F); or, average condensing     K or k   thermal conductivity of material of tube, or
                                                                                                             2
                                                                      2
                                     coefficient on outside of tube, Btu/(hr)(ft )          other, wall, Btu/(hr)(ft )(°F/in.).
                                     (°F); or, U t   average of horizontal and ver-    k   k 1   thermal conductivity of liquid, Btu/
                                     tical transfer film coefficients in still air; or,     (hr)(°F/ft); or, thermal conductivity of insu-
                                                                                                          2
                                     convection heat transfer film coefficient,             lation, Btu/(hr)(ft )(°F/ft); or, when speci-
                                                                                                        2
                                              2
                                     Btu/(hr)(ft )(°F).                                    fied, Btu/(hr)(ft )°F/(in.).
                                h cm   average value of condensing film coeffi-    k or k a    thermal conductivity of fluid at average of
                                      cient, for vertical rows of horizontal tube,          temperatures, t 1 and t 2 , Btu/(hr)(°F/ft); or,
                                              2
                                                                                                    2
                                      Btu/(hr)(ft )(°F).                                    Btu/(hr)(ft )(°F/ft).
                                h fg   latent heat of vaporization or evaporation,     k f   thermal conductivity at film temperature,
                                                                                                    2
                                      Btu/lb.                                               Btu/(hr)(ft )(°F/ft).
                                 h i   film coefficient of fluid on inside of tube,    k g   gas phase mass transfer coefficient, lb
                                                                                                     2
                                              2
                                      Btu/(hr)(ft )(°F).                                    mol/(hr)(ft )(atm).
                                                                                                     2
                             h io , h io     inside film coefficient referred to outside of  k d   diffusivity , ft /hr.
                                      tube surface (plus including condensing          k L   thermal conductivity of saturated liquid,
                                      film coefficient clean basis for Colburn-             Btu/(hr)(°F/ft).
                                                                2
                                      Hougen calculations), Btu/(hr)(ft )(°F).         k w   thermal conductivity of material of wall,
                                                                                                        2
                                 h l   h lt    nucleate boiling coefficient for an          (Btu-ft)/[(hr)(ft )(°F)].
                                                         2
                                     isolated tube, Btu/(hr)(ft )(°F).                 L   length of straight tube for heat transfer (or,
                                h ga   volumetric gas phase coefficient,                    nominal tube length), ft; or, length of path,
                                              3
                                      Btu/(hr)(ft )(°F).                                    ft; or, length or thickness of coil or jacket, ft;
                                 h la   liquid phase heat transfer coefficient,             or, superficial liquid mass velocity,
                                              2
                                                                                                   2
                                      Btu/(hr)(ft )(°F).                                    lb/(hr)(ft ); or, equivalent length of pipe, ft;
                                h M   effective heat transfer film coefficient,             or, thickness of insulation, in.
                                              2
                                      Btu/(hr)(ft )(°F).                               L c   thickness, ft.
                                h m   film coefficient evaluated at length mean  t     L e   net effective tube length, ft.
                                                           2
                                      for vertical tube, Btu/(hr)(ft )(°F).            L f   finned length of each tube, ft.
                                h Nu   condensing film coefficient by Nusselt          L o   length of shell; or, length of one tube pass, ft.
                                                      2
                                      equation, Btu/(hr)(ft )(°F).                     L t   total length of tubing required, ft.
                                 h o   dry gas coefficient on shell side for partial   L w   thickness of tube wall, in.; or, ft as consistent
                                                        2
                                     condensers, Btu/(hr)(ft )(°F); or, (for bare           with other units.
                                     or plain tubes) film coefficient outside of       L v   weighted average latent heat of reboiler
                                                          2
                                     tube in bundle, Btu/(hr)(ft )(°F); or, (for fin        vapor, Btu/lb.
                                     tubes) outside film coefficient corrected to  LMTD   log mean temperature difference, °F.
                                                       2
                                     base of fin, Btu/(hr)(ft of outside area)(°F).     l   length of each individual tube, ft; or, fin
                                 h r   radiation heat transfer film coefficient,            height, in.
                                              2
                                      Btu/(hr)(ft )(°F).                               l v   latent heat of vaporization, Btu/lb.
                                 h s   film coefficient for boiling fluid, Gilmour     M   net free distance (sum) of space between
                                                                    2
                                      equation, Equation 10-165, Btu/(hr)(ft )              tubes from wall to wall at center of shell
                                     (°F); or, subcooling film coefficient,                 circle, in.; or, molecular weight.
                                     pcu/(hr)(ft)(°F).                                M a   average molecular weight.
                                 h st   theoretical boiling film coefficient for single  M v   average molecular weight of vapor.
                                                   2
                                      tubes, Btu/(hr)(ft )(°F).                        m   exponent for baffle tray columns.
                               htc a   air-side heat transfer coefficient,         N or N t   total number of tubes in bundle.
                                              2
                                      Btu/(hr)(ft )(°F).                               N   number of tube holes per tubesheet; or,
                               hct c   tube-side heat transfer coefficient,                 number of fins per in. on tube; or, agitator
                                              2
                                      Btu/(hr)(ft )(°F).                                    or impeller speed, revolutions/hr; or, num-
                                  J   Colburn factor.                                       ber of tubes in bundle; or, number
                                 J 4   Colburn factor for equation proposed by              tubes/row in direction of air flow.
                                      Pierce.                                          N a   average number of tubes in a row in circular
                                 j H   factor in heat transfer equations, dimension-        shell of multitube condenser.
                                      less.                                            N c   number of baffles.
                                 K   thermal conductivity of fluid,                   N nv   number of holes in vertical center row of
                                      Btu/(hr)(ft)(°F). (Used by Permission:                bundle.
                                      Brown Fintube Company.)                         N t     number of tubes used, for condensing.
                                                                 2
                                 K g   diffusion coefficient, lb mol/(hr)(ft )(atm).   N v   number of rows of tubes in a vertical tier.
                                 K L   thermal conductivity of saturated liquid,      N vc   number of rows of tubes in a vertical tier at
                                      Btu/(hr)(°F/hr).                                      centerline of exchanger.
   311   312   313   314   315   316   317   318   319   320   321