Page 233 - APPLIED PROCESS DESIGN FOR CHEMICAL AND PETROCHEMICAL PLANTS, Volume 1, 3rd Edition
P. 233

205











































































                                              CAPACITY-GALLONS PER  MINUTE  (at  bep)
          Figure 3-57. Viscosity performance correction chart for small centrifugal pumps with capacity at best efficiency point of  less than 100 GPM
          (water performance). Note: Do not extrapolate. For small centrifugal pumps only, not for axial or mixed flow. NPSM must be adequate. For
          Newtonian fluids only. For multistage pumps, use head per stage. (By permission, Hydraulic lnstitufe Standards for Centrifugal, Rotav, and
          Reciprocating Pumps, 13th ed.,  Hydraulic Institute, 1975.)
   228   229   230   231   232   233   234   235   236   237   238