Page 233 - APPLIED PROCESS DESIGN FOR CHEMICAL AND PETROCHEMICAL PLANTS, Volume 1, 3rd Edition
P. 233
205
CAPACITY-GALLONS PER MINUTE (at bep)
Figure 3-57. Viscosity performance correction chart for small centrifugal pumps with capacity at best efficiency point of less than 100 GPM
(water performance). Note: Do not extrapolate. For small centrifugal pumps only, not for axial or mixed flow. NPSM must be adequate. For
Newtonian fluids only. For multistage pumps, use head per stage. (By permission, Hydraulic lnstitufe Standards for Centrifugal, Rotav, and
Reciprocating Pumps, 13th ed., Hydraulic Institute, 1975.)