Table 50.22 Characteristics of sealed Dtyfit batteries A300 series for standby operation
~~
Type No. and Nominal Nominal Discharge Weight Length Width Height Max. Power/ Power/ Mux. Interchangeable
type code* volfage capacity jur current for (approx.) (mm) (mm) to top height weighf volume load with*
(V) 10hdischarge 10hdischarge (g) of lid over ratio ratio (upprox.)
(Ah) (mA) (mm) contacts/ (W hkg) (W h/dm3) (A).F
cover
(mm)
07 1 91172 00 6 1.0 100 245 51.0 42.0 50.0 54.4 24.5 56.0 40 -
A300-6V-I.OAh-S
07 1 91182 00 6 1.1 110 285 97.0 25.0 50.5 54.9 23.2 54.0 40 4 x R14/
A300-6V-l.lAh-S UM2IBabylC
07 191185 00 12 1.1 I10 540 96.8 49.0 50.5 54.9 24.4 55.0 40 8 x R14/
A300-12V-I. 1Ah-S UM2Baby/C
07 1 91262 00 6 2.0 200 460 75.0 51.0 53.0 57.4 26.1 59.1 60 -
A300-6V-2.0Ah-S
07 1 91302 00 4 3.0 300 415 90.0 34.0 60.0 64.4 28.9 65.4 60 -
A300-4V-3.0Ah-S
07 1 91312 00 6 3.0 300 620 134.0 34.0 60.0 64.1 29.6 65.8 60 4 x R201
A300-6V-3.0Ah-S UMl /Mono/D
07 1 91432 00 12 5.7 570 2225 151.2 65.0 94.0 98.4 30.7 74.0 80 -
A300- 12V-5.7Ah-S
07 1 91472 00 6 6.5 650 1230 116.0 50.5 90.0 94.4 31.7 73.9 80
A300-6V-6.5Ah-S
07 I 91502 00 2 9.5 950 575 52.5 50.0 94.0 98.4 33.0 77.0 80
A300-2V-9.5Ah-S
07 I91523 00 6 9.5 950 1710 151.2 50.0 94.0 98.4 33.3 80.2 80
A300-6V-9.5Ah-S
07 191525 00 12 9.5 9 50 3380 151.0 97.0 94.0 98.4 33.7 82.7 80
A300- 12V-9.5Ah-S m
I
8.
* The last letter of the type code indicates the type of terminals Q