338    Centrifugal Pumps: Design and Application




























                            Figure 16-1. Shaft section.
















         Yield strength of 4140 steel is 80,000 psi.
         The endurance limit for 4140 steel is 52,500 psi. This limit must be
         adjusted to account for the service condition (Shigley).




         For 99% reliability use K c = .814. For ground surface finish use K a
         = .9. For stress concentration due to locating ring groove radius:






         where K t is the stress concentration factor from Peterson.
   368   369   370   371   372   373   374   375   376   377   378